Output Voltage |
From 12 V to 58 V (Refer model number matrix table)
|
|
Output Power |
1000W Fan Cooled,Peak 1200W for 1mS
|
|
Output Voltage Adjustment |
+/-3 % |
|
Hold-up Time |
120 VAC: 8 ms and 240 VAC: 8 ms |
Line Regulation |
+/-0.5 % |
|
Load Regulation |
+/-1 % |
|
Minimum Load |
0.0 A |
|
Transient Response |
max excursion 10 %; 50-100 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. |
|
Ripple1 |
2.0 % max for all outputs. |
|
Rise Time |
< 100 ms |
|
Set Point Accurarcy |
+/-1 % |
|
Over Current Protection |
110 % Typ, Hiccup Type, Autorecovery |
|
Over Voltage Protection |
114 %, Latch Type ,AC Power to be recycled for recovery |
|
Over Temperature Protection |
130-140°C primary heat sink, autorecovery |
|
Short Circuit Protection |
Latch Type ,AC Power to be recycled for recovery |
|
Current Share |
up to 3 supplies can be connected in parallel (optional) |
|
Cooling |
Fan Cooled : 1000W |
|